E08-4in1 Module Converter DYP-E08
E08-4in1 Module Converter
Module : DYP-E08
The E08 4 in 1 module converter is a functional convert module, which can control 1 to 4 modules of for simultaneous, cross or polling work. The response time of the module converter is determined according to the actual output interface. By using this module converter to detect and monitor the distance of different scenario, different directions, and multiple ranging modules.
Here comes the detailed specifications of DYP-E08 :
Item | UART Controlled output | RS485 Output | IIC output | Switch Output | Unit | Remark |
Operating Voltage | 5~24 | 5~24 | 5~24 | 5~24 | V | DC |
Operating current | ≤5 | ≤9 | ≤7 | ≤9 | mA | / |
Operating cycle | Controlled | Controlled | Controlled | Controlled | / | / |
Output interface | UART Controlled | RS485 | IIC | Switch | / | / |
Remarks:
Rated Environmental Condition
Item | Minimum value | Typical value | Max value | Unit |
Storage Temp | -25 | 25 | 75 | ℃ |
Storage Humidity | / | 65% | 90% | RH |
Operating Temp | -15 | 25 | 60 | ℃ |
Operating Humidity | / | 65% | 80% | RH |
Remark:
1.Environment temperature is 0-39℃, max humidity is 90%(Non-condensation);
2.Environment is 40-50℃, max humidity is the highest at current temperature in nature.
Rated Electrical Condition
Item | Minimum value | Typical value | Max value | Unit | Remark |
Operating voltage | 5 | 12 | 24 | V | / |
Peak current | / | / | 50 | mV | Peak value |
Input Ripple | / | / | 100 | mV | Peak value |
ESD | / | / | ±4K/±8K | V | / |
Remark : The probe shell and output pin comply with the IEC61000-4-2 standard. Contact static electricity±4KV, Air static electricity±8KV.
Product Features
The DYP-E08 four-in-one power conversion module features a wide voltage power supply of DC5-24V, ensuring compatibility with diverse power sources. It supports simultaneous connection of 1 to 4 ranging modules, enabling flexible configuration. With a working temperature range of -15℃ to +60℃, the module maintains stable operation in various environments. Its data output is stable and reliable, guaranteeing accurate measurement results.
The module allows two installation modes: installing four ranging modules separately for multi-directional distance detection, or arranging them in the same direction for distance confirmation. When four modules work simultaneously, it delivers a fast response time, enhancing real-time performance. Equipped with an anti-static electricity design compliant with the IEC61000-4-2 standard, it ensures reliable protection against electrostatic discharges in industrial applications.
Model Selection
The output format of this series of ranging modules is divided into 4 formats. If there are special requirements that need to modify the response time, angle, communication agreement etc., you need to communicate with our FAE engineers during purchasing.
| No. | Output interface | Model No. |
| E08 series | UART | DYP-E08TF-V1.0 |
| IIC | DYP-E08CF-V1.0 | |
| RS485 | DYP-E084F-V1.0 | |
| SWITCH | DYP-E08GDF-V1.0 |
Reliable Testing Condition
No. | Description | Testing condition | Sample QTY |
1 | High temperature and humidity | 65℃,85%RH,Power ON@5V,72hrs | 3 |
2 | low temperature | -20℃,Power ON@5V,72hrs | 3 |
3 | High temperature And humidity storage | 80℃,80%RH,storage,72hrs | 3 |
4 | Low temperature storage | -30℃,storage,72hrs | 3 |
5 | Vibration test | 10-200Hz,15min,2.0G, XYZ three axes,each axis is 0.5 hours | 3 |
6 | Drop test | 120cm free fall,5 times on wooden floor | 3 |
Note : After the test, the module is determined to be OK after the function test, and the performance degradation rate is≤10%.
Note
1.Please pay attention to the structural tolerances when designing. Unreasonable structural design may cause temporary abnormalities in module functions.
2.Please pay attention to the evaluation of electromagnetic compatibility when designing. Unreasonable system design may cause malfunction of the module.
3.When the boundary application of the product limit parameter is involved, you can contact after sale service dept.to confirm the relevant precautions.