High Performance Ultrasonic Precision Range Finder DYP-ME007YS
The module adopts Transmitter and receiver integrated probe and anti-water probe design.
The sensor is stable and reliable and has a long life span, which is highly adaptable to the poor working condition.
The module has a built-in high-precision ranging algorithm and power management program, with high ranging accuracy and low power consumption.
High Performance Ultrasonic Precision Range Finder
Module : DYP-ME007YS
DYP-ME007YS transceiver integrated waterproof ultrasonic distance measurement sensor adopts a transceiver integrated enclosed waterproof cable probe with a certain level of dust and water resistance, suitable for wet and harsh measurement occasions. This series has three different output modes and is a commercial-grade functional module with simple operation, high performance and high reliability.
Here comes the detailed specifications of DYP-ME007YS :
Parameters | PWM | TX | KG | Unit | Remarks |
Operating voltage | 5 | V | DC | ||
Average current | <8 | mA | / | ||
Blind spot distance | 0~28 | cm | / | ||
Flat object measurement range | 28~450 | cm | / | ||
Output method | PWM pulse | UART serial | TTL level switch | - | / |
Work period | Controlled | 100 | 100 | ms | / |
Measurement accuracy | ±(1+s*0.5%) | ±(1+s*0.3%) | cm | / | |
Temperature compensation | No compensate | Compensate | - | / | |
Sensor frequency | 40K±1.0K | Hz | / | ||
ESD | ±4/±8 | KV | / | ||
Remarks:
(1) Typical data of 100ms working cycle.
(2) For the data measured on a 50cm*60cm flat carton, the default sensing area threshold of the switch quantity is 100cm.
(3) The probe shell and output pins meet the IEC61000-4-2 standard.
Rated Environmental Condition
Items | Minimum | Typical value | Maximum | Unit |
Storage temperature | -25 | 25 | 80 | °C |
Storage humidity | / | 65% | 90% | RH |
Operating temperature | -15 | 25 | 60 | °C |
Operating humidity | / | 65% | 80% | RH |
Remarks : a. When the ambient temperature is 0-39°C, the maximum humidity is 90% (non-condensing);
b. When the ambient temperature is 40-50°C, the highest humidity is the highest humidity in nature at the current temperature (non-condensing).
Rated Electrical Condition
Items | Specification | Unit | Remarks | ||
Minimum | Typical value | Maximum | |||
Operating voltage | 4.9 | 5.0 | 5.05 | V | / |
Peak current | / | / | 50 | mA | When 5V power |
Input ripple | / | / | 50 | mV | Peak to peak |
Input noise | / | / | 100 | mV | Peak to peak |
ESD | / | / | ±200/±2K | V | / |
ESD | / | / | ±4K/±8K | V | / |
Remarks : The static electricity specification of the assembly line body, the contact static electricity should not be higher than ±200V, and the air static electricity should not be higher than ±2KV.
Product Features
DYP-ME007YSultrasonic sensor boasts several notable features. It offers high sound pressure output and operates on a 5V power supply, with a standby current that can be lower than 60μA, ensuring low power consumption. It supports multiple output modes, including UART serial port automatic output, PWM controlled output, and switch output, providing flexibility for various applications. The ultrasonic distance meter sensor comes with a one-piece enclosed cable probe and has a center frequency of 40KHz.
It incorporates temperature compensation to maintain accuracy across its working temperature range of -15°C to +60°C, while its storage temperature range extends from -25°C to +80°C. The measurement accuracy is ±(1cm+S*0.3%), where S is the measured value. Additionally, it features an electrostatic protection design, with electrostatic protection devices added to the probe shell and I/O pins, complying with the IEC61000-4-2 standard.



Scope of Application



Model Selection
The output format of this series of ranging modules is divided into 4 formats. If there are special requirements that need to modify the response time, angle, communication agreement etc., you need to communicate with our FAE engineers during purchasing.
| No. | Output Interface | Model |
| ME007YS Series | UART AUTO | DYP-ME007YS-TX V2.0 |
| UART CONTROLLED | DYP-ME007YS-TX1 V2.0 | |
| PWM | DYP-ME007YS-PWM V2.0 | |
| SWITCH VALUE | DYP-ME007YS-KG V2.0 |
Matters Needing Attention
1. The company reserves the right to change this document and update the functions without prior notice.
2. Please pay attention to the structural tolerances when designing. Unreasonable structural design may cause temporary abnormalities in module functions.
3. Please pay attention to the evaluation of electromagnetic compatibility when designing. Unreasonable system design may cause malfunction of the module.
4. When the boundary application of the product limit parameter is involved, you can contact our FAE to confirm the relevant precautions.
Packaging Specifications
1. The default is Denyong's conventional packaging method.
2. Single-module independent electrostatic bag packaging can be used for small orders, 180pcs per carton, including 9 medium bags, 20pcs for each medium bag.
3. Packaging materials can be customized according to customer IQC related standards.
4. The container transportation method needs to adopt the staggered consolidation method, and at the same time, the outer edge of the single stack needs to be wrapped with a reinforced gusset to provide sufficient support.